Mastering Fire Alarm Systems & Project Design

Fire Alarm and Fire Suppression Systems

Fire Alarm and Fire Suppression Systems (Level 1)

  • Introduction to Fire Alarm Systems International Standards for Fire Alarm Systems American Code – NFPA 72 الكود الأمريكي
  • British Standard Code – BS5839 الكود البريطاني
  • European Standard – EN54 الكود الأوروبي
  • Accreditation Bodies ( UL – ULC – FM – LPCB – VDS ) جهات الإعتماد العالمية
  • Fire Alarm System Vendor List قائمة الموردين المعتمدين
  • Types of Fire Alarm Control Systems:

Conventional , Addressable , Intelligent and Wireless Fire Alarm Systems Conventional Fire Alarm Control Systems

Fire Alarm Detectors

Smoke Detectors

Photoelectric Smoke Detectors ( Coverage – Spacing – Installation – Testing – Maintenance )

Smoke Detectors Applications for Flat Ceiling including Partitions & Obstructions

Smoke Detectors Applications for Sloped Ceiling

Smoke Detectors Applications for Suspended Ceiling & Raised Floor

Beam Smoke Detectors ( Coverage – Spacing – Installation – Testing – Maintenance )

Electrical Metro Station Application

Aspirating Smoke Detectors ( Coverage – Spacing – Installation – Testing – Maintenance )

Server Room Application

Duct Smoke Detectors ( Coverage – Spacing – Installation – Testing – Maintenance )

Clean Room Application

Heat Detectors

Fixed Temperature Heat Detectors ( Coverage – Spacing – Installation – Testing – Maintenance )

Rate of Rise Heat Detectors ( Coverage – Spacing – Installation – Testing – Maintenance )

Hotel Kitchen Application

Linear Heat Detectors ( Coverage – Spacing – Installation – Testing – Maintenance )

Subway Tunnel Application

Rate Anticipation Heat Detectors ( Coverage – Spacing – Installation – Testing – Maintenance )

Production Line Application

Gas Detectors

Toxic Gases

Asphyexiant Gases

Flammable Gases

Low Density Gas Detectors ( Coverage – Spacing – Installation – Testing – Maintenance )

Low Density Gas Detectors Application

Equi Density Gas Detectors ( Coverage – Spacing – Installation – Testing – Maintenance ) \

Equi Density Gas Detectors Application

High Density Gas Detectors Application

Flame Detectors

IR Flame Detector ( Coverage – Spacing – Installation – Testing – Maintenance )

IR Flame Detector Application

UV Flame Detector ( Coverage – Spacing – Installation – Testing – Maintenance )

UV Flame Detector Application

IR & UV Flame Detector ( Coverage – Spacing – Installation – Testing – Maintenance )

IR & UV Flame Detector Application Manual Call Point ( MCP) ( Single Action – Dual Action – Key Operated – Break Glass )

Manual Call Point ( MCP) ( Standards – Spacing – Installation – Testing – Maintenance )

Manual Call Point Applications Fire Alarm Sounders Sounders ( Standards – Selecting – Spacing – Installation – Testing – Maintenance )

NAC Voltage Drop Calculation

Single Zone & Two Sounder Circuits Applications

Four Zones & Two Sounder Circuits Applications

Twelve Zones & Four Sounder Circuits Application

Outdoor Flashers ( Standards – Spacing – Installation – Testing – Maintenance )

Flasher Candela Calculation Fire Alarm Speakers ( Standards – Spacing – Installation – Testing – Maintenance )

Fire Alarm Speakers with Public Address Application

Fire Alarm Network Fire Alarm Boxes ( Pull – Back – Junction )

Fire Alarm Pipes ( PVC – EMT ) Buried Network ( Pipes – Boxes – Cables )

Exposed Network ( Pipes – Boxes – Cables )

Fire Alarm Cables (Standards – Installation – Testing – Maintenance)

Fire Alarm Retardant Cables

Fire Alarm Resistant Cables (Cat CWZ – PH30 – PH60 – PH120)

Fire Alarm Armored Cables (Practical Sessions)

Practical Training on Conventional Fire Alarm Systems

Practical Training on Suppression Fire Alarm Systems Interfacing Fire Alarm System with (HVAC – Power – Smoke Fan – Solenoid Valve)


 

Fire Alarm and Fire Suppression Systems (Level 2)

Addressable Fire Alarm Control Panel

• Addressable Control Panel Components

• How does it work

• Signaling Line Circuit (SLC)

• Loop Data Communication

• Polling, Polling Time, Loop Interrupt

• Loop Maximum Distance

• Loop Resistance

• Loop Current

• Loop Protection

 Detector Address & Numbering Plan

• DIP Switches

• XPERT Cards

• Rotary Switches

• Handheld Programmers

• Auto Learn

Addressable Detectors

• Addressable Smoke Detectors

• Addressable Heat Detectors

• Addressable Multicriteria Detectors (Multi-Detectors)

• Addressable Beam Detectors

• Addressable Duct Detectors

• Linear Heat Detectors wiring to Addressable FACP

Addressable Modules

• Monitor Modules /Zone Module / Input Module

• Control Module /Signal Module / Output Module

• Relay Module

• Input/ Output Modules / Transponders

• Isolator Modules / Fault Module

• Open Circuit Conditions

• Short Circuit Conditions

Addressable FACP Annunciators

• LED Annunciators

• LCD Annunciators

• Mimic Annunciators

• Graphic Annunciators

NFPA Wiring Standards

• Class A Style 6

• Class A Style 7

• Class A Style D

• Class A Style Z

• Class B Style 4

• Class B Style B

• Class B Style Y

Addressable FACP Networking

• RS485

• Fiber

• IP Network

Addressable FACP with BMS System

• BACnet Module

• BACnet Interface

NFPA 101 (Life Safety Code)

• Assembly (Theater , Cinema , Bus Station & Train Station)

• Industry

• Storage

• Business

• Hotels

• Education

• Mercantile

Fire Alarm Network

• Fire Alarm Race ways

• Fire Alarm Pipes

• Fire Alarm Boxes

• Fire Alarm Cables

• Including Calculation of Number of Permitted Cables in a Conduit

 Fire Alarm Interfacing with other systems

• Extinguishing systems such as automatic sprinkler systems

• Power interruption and elevator recall

• Smoke management

• HVAC fan and damper controls

• Door unlocking and door release.

• Security systems • Mass notification systems

• Monitoring of fire extinguishers

• Including Voice Alarm System & Telephone Emergency System

• Wireless Fire Alarm Systems


 

Fire Alarm and Fire Suppression Systems (Level 3)

• Preparing Fire Matrix
• Preparing Excel Sheet
• Addressable Simplex Programming & Maintenance
• Intelligent Notifier Programming & Maintenance
• Addressable Fire Control Panel (Programming & Maintenance)
• Intelligent Fire Control Panel (Programming & Maintenance)

Fire Alarm Projects Technical Office

• Fire Alarm System Projects (Including Shop Drawing & Riser Diagram)

• Fire Alarm System for a Bank

• Fire Alarm System for Warehouse

• Fire Alarm System for a Hospitals

• Fire Alarm System for a Factory

• Fire Alarm System for a School

• Fire Alarm System for a Hotel

• Fire Alarm System for a Mall

• Fire Alarm Systems for a Cinema & Theatre

• Fire Alarm System for a University

• Fire Alarm System for a High-Rise Building

• NFPA 2001
• Introduction to Fire Suppression Systems
• Fire Suppression Systems Using FM-200
• Fire Suppression Systems Using CO2
• Fire Suppression Systems Using NOVEC- 1230

if you would like to register, kindly press here and fill your information  . . .

Jelecom Egypt

Jelecom is an Egyptian Company which has professional Engineers for Engineering Projects and it provides Technical Training and Solutions for both Engineers and Technicians in Industry & Academy

Contact Us

🗺️Address:

Building No. 73, Ramsis Street, downtown, in front of the High Court, Gamal Abdel Nasser Metro – Cairo, Egypt.

 73 ش رمسيس الدور الثانى أمام دار القضاء العالي محطة مترو جمال عبدالناصر - وسط البلد - القاهرة

 

📱Tel ( For Training ):

01011981001  - 02 25777 134
01022612092 - 02 25777 135
01022612094 - 02 25777 137
01022612095 - 02 25777 139

📱Tel ( For Sales ):

01001605695
01008636386
01000480103
01000480104

 

📧E-Mail :

info@jelecom.com